Smoke Density Measurement Tester
Smoke Density Measurement Tester
Smoke Density Measurement Tester
DIN EN 61034-1 is a regulatory standard that defines the standard testing method for measuring smoke density generated during the combustion of electrical cables.
The Smoke Density Measurement Tester is particularly applicable to low-smoke cables used within buildings, with the purpose of ensuring visibility and securing human safety in the event of a fire.
Key Features

Accurate Smoke Density Measurement Designed in full compliance with DIN EN 61034-1, the equipment measures the light transmittance of smoke generated in fire conditions in real time, enabling precise evaluation of smoke density.
Advanced Optical Measurement System The built-in photometric system precisely measures the degree of light obstruction caused by smoke during cable combustion.
This equipment enables the evaluation of low-smoke performance required for a safe environment.
Automated Testing and Data Analysis Through an automated combustion system and fan, smoke is evenly mixed, and results can be easily analyzed and recorded after the test is completed. Data is output in graph format for intuitive interpretation.
Enhanced Safety and Efficiency This equipment meets safety standards related to cable installation within buildings and supports the development of cable products that minimize smoke generation during fires. In addition, the testing process is efficiently designed, contributing to time and cost savings.
Equipment Specifications
Specifications
| Test Specimen | Electrical wires, cables, plastic components, etc. |
| Test Standard | DIN EN 61034-1 (Smoke Density Measurement – Measurement Method) |
| Light Transmittance Measurement Method | Photometric sensor and potentiometer recording device |
| Light Source – Detector Distance | Approx. 3,000 mm (per EN standard) |
| Light Source | White light or standardized helium-neon laser (He-Ne) |
| Measurement Parameters | Smoke density, light transmittance (%) |
| Test Chamber Size | 3,320 × 3,320 × 3,250 mm (W × D × H) |
| Test Chamber Material | Heat-resistant steel plate with black-painted interior finish |
| Ignition Source | Standardized alcohol mixture flame |
| Combustion Time Setting | 0 ~ 999 sec (automatic timer control) |
| Data Logging | Electronic data logging (software-integrated) |
| Calibration Function | Built-in software-based automatic calibration |
| Power Supply | 230 VAC, 50/60 Hz |
| Equipment Weight | Approx. 1,000 kg |
| Safety Devices | Gas shut-off valve, overheat protection, emergency stop switch, etc. |
Software Support Specifications

Automatic Calibration Supports automatic calibration before and after testing via software.
Data Recording Real-time electronic measurement data recording and storage.
Graph Analysis Visually analyzes test data and displays it in graph form.
Data Output Outputs data and reports in CSV, Excel, and PDF formats.
Remote Control Remote monitoring and control via Wi-Fi or Ethernet.
Notification Function Provides automatic alarms for out-of-specification conditions or excessive temperatures during testing.
Compatibility Compatible with Windows operating systems; supports USB/Ethernet connections.
The Analytical Technology Trusted by 100+ Clients.
Partner with S&T Today.
Elevate your analytical environment with our precision technology and accumulated expertise.

Company Name : SNT CEO: Lee Woo-jong
Address: W 1013, The Front Misa, 11 Misagang-byeonjungang-ro, Hanam-si, Gyeonggi-do
Business Registration Number: 314-24-80398
Phone: 031-794-7980 Consultation Hours: Weekdays 09:00–18:00 (Closed on weekends and public holidays)
Smoke Density Measurement Tester
DIN EN 61034-1 is a regulatory standard that defines the standard testing method for measuring smoke density generated during the combustion of electrical cables. The Smoke Density Measurement Tester is particularly applicable to low-smoke cables used within buildings, with the purpose of ensuring visibility and securing human safety in the event of a fire.
Key Features

Accurate Smoke Density Measurement Designed in full compliance with DIN EN 61034-1, the equipment measures the light transmittance of smoke generated in fire conditions in real time, enabling precise evaluation of smoke density.
Advanced Optical Measurement System The built-in photometric system precisely measures the degree of light obstruction caused by smoke during cable combustion. This equipment enables the evaluation of low-smoke performance required for a safe environment.
Automated Testing and Data Analysis Through an automated combustion system and fan, smoke is evenly mixed, and results can be easily analyzed and recorded after the test is completed. Data is output in graph format for intuitive interpretation.
Enhanced Safety and Efficiency This equipment meets safety standards related to cable installation within buildings and supports the development of cable products that minimize smoke generation during fires. In addition, the testing process is efficiently designed, contributing to time and cost savings.
Specifications
Test Specimen | Electrical wires, cables, plastic components, etc. |
Test Standard | DIN EN 61034-1 (Smoke Density Measurement – Measurement Method) |
Light Transmittance Measurement Method | Photometric sensor and potentiometer recording device |
Light Source – Detector Distance | Approx. 3,000 mm (per EN standard) |
Light Source | White light or standardized helium-neon laser (He-Ne) |
Measurement Parameters | Smoke density, light transmittance (%) |
Test Chamber Size | 3,320 × 3,320 × 3,250 mm (W × D × H) |
Test Chamber Material | Heat-resistant steel plate with black-painted interior finish |
Ignition Source | Standardized alcohol mixture flame |
Combustion Time Setting | 0 ~ 999 sec (automatic timer control) |
Data Logging | Electronic data logging (software-integrated) |
Calibration Function | Built-in software-based automatic calibration |
Power Supply | 230 VAC, 50/60 Hz |
Equipment Weight | Approx. 1,000 kg |
Safety Devices | Gas shut-off valve, overheat protection, emergency stop switch, etc. |
Software Support Specifications

- Automatic Calibration Supports automatic calibration before and after testing via software.
- Data Recording Real-time electronic measurement data recording and storage.
- Graph Analysis Visually analyzes test data and displays it in graph form.
- Data Output Outputs data and reports in CSV, Excel, and PDF formats.
- Remote Control Remote monitoring and control via Wi-Fi or Ethernet.
- Notification Function Provides automatic alarms for out-of-specification conditions or excessive temperatures during testing.
- Compatibility Compatible with Windows operating systems; supports USB/Ethernet connections.
100+ Clients Trust Our Analytical Technology
Start working with SNT Korea today.
Contact us for detailed technical consultation and measurement inquiries.

Company Name : SNT Address: W 1013, The Front Misa, 11 Misagang-byeonjungang-ro, Hanam-si, Gyeonggi-do
Business Registration Number: 314-24-80398 CEO: Lee Woo-jong Phone: 031-794-7980 Consultation Hours: Weekdays 09:00–18:00 (Closed on weekends and public holidays)
Privacy Policy Terms of Service COPYRIGHTS (C) 2026. ALL RIGHTS RESERVED.