Inverse Gas Chromatography Surface Energy Analyzer-Nova

The iGC-SEA Nova, the latest addition to the Inverse Gas Chromatography Surface Energy Analyzer (iGC-SEA) line, retains all the unique capabilities of the original iGC-SEA instrument while offering the added ability to dry samples under high-temperature conditions. 

Applications 


Battery Materials Analysis — Measures surface energy and diffusion properties of electrode materials at high temperatures, contributing to performance enhancement Catalyst and Sorbent Research — Analyzes sorption strength and surface reactivity to enable efficient catalyst design Polymer and Composite Material Characterization — Evaluates adhesion and miscibility to understand interactions between materials Carbon-Based Materials Analysis — Precisely characterizes the surface properties of graphene, carbon nanotubes, and similar materials for advanced electronic materials development Pharmaceuticals and Active Pharmaceutical Ingredients (APIs) — Analyzes crystallinity, surface energy, and wettability to evaluate formulation stability and blending compatibility Fibers and Textiles — Analyzes surface modification status and energy changes before and after treatment, supporting evaluation of dyeability and functional treatment efficiency

Key Features 




  • High-Temperature Analysis Capability — Analyzes sample surface properties and diffusion coefficients across a temperature range of 30 °C to 500 °C, providing an advantage for material characterization under high-temperature environments
  • In-Situ Sample Pre-Treatment — Modular accessories enable direct sample pre-treatment within the instrument, allowing analysis under various conditions while maintaining sample integrity
  • Versatile Probe Gas Selection — Precisely measures diverse material properties — including surface energy, acid-base interactions, and sorption isotherms — using up to 12 different probe gases
  • Fully Automated Operation — Dedicated software enables experimental automation, with a user-friendly interface that simplifies experimental setup and data analysis
  • Optional Humidity Control — An optional humidity control feature can be added, enabling analysis of sample property changes under diverse humidity conditions

What Are the Advantages 

of iGC-SEA? 


01

High-Temperature Capability 


With a temperature range of 30 °C to 500 °C, the iGC-SEA Nova's high-temperature column oven enables laboratories to perform sample preparation, surface energy analysis, and determination of diffusion coefficients — such as for carbon materials — at application-relevant temperatures. 


02

Rapid Surface Characterization of Highly Active Substrates 


The iGC-SEA Nova efficiently characterizes highly active substrates through its rapid surface analysis capabilities. 


03

Unmatched Accuracy and Reliability 


The iGC-SEA Nova from Surface Measurement Systems combines Inverse Gas Chromatography principles with innovative instrument features to deliver outstanding accuracy and exceptional reproducibility. 


04

Fully Automated Operation 


Through the innovative design of the Inverse Gas Chromatography Surface Energy Analyzer Nova and its dedicated control software, experiments can be performed with complete automation — dramatically reducing user hands-on time. 


05

Experimental Flexibility with Up to 12 Probe Gases   


Using up to 12 different probe gases, researchers can conduct diverse experiments and obtain a broad range of Inverse Gas Chromatography data. 


06

In-Situ Sample Pre-Treatment  


Modular accessories enable direct sample pre-treatment within the instrument, allowing researchers to precisely track how solid surface properties change under various temperatures and conditions. 

Inverse Gas Chromatography Surface Energy Analyzer: iGC-SEA Nova  

The iGC-SEA Nova delivers a diverse range of innovative material characterization capabilities. 

iGC-SEA NOVA Specifications 


Specifications 


Temperature Range30°C ~ 500°C (high-temperature column oven installed)
Number of Probe GasesUp to 12 different probe gases available
Sample Pre-TreatmentIn-situ pre-treatment supported (via modular accessories)
Operation ModeFully automated experiment execution (dedicated control software included)
Accuracy & ReproducibilityHigh accuracy and reproducibility achieved through iGC principles and innovative instrument capabilities
Humidity Control OptionRelative humidity control 0% ~ 90% (when optional humidity module is used)
Data Analysis SoftwareUser-friendly iGC wizard-based software provided
Application AreasBattery materials, catalysts, polymers, carbon materials, and various other high-temperature applications

Inverse Gas Chromatography Technique   

Surface Characterization of Carbon Black for Energy Storage 

Vulcan XC 72 is a highly electrically conductive carbon black used in a wide range of applications, including batteries, fuel cells, conductive papers, and catalyst supports. 


This material offers exceptional conductivity and plays a critical role as a support material in both anode and cathode electrodes at low loading levels — particularly in Polymer Electrolyte Membrane Fuel Cells (PEMFCs). BET SSA: 128.8 m²/g. 

The Analytical Technology Trusted by 100+ Clients.  
Partner with S&T Today. 

Elevate your analytical environment with our precision technology and accumulated expertise. 


Company Name : SNT    CEO: Lee Woo-jong

Address:  W 1013, The Front Misa, 11 Misagang-byeonjungang-ro, Hanam-si, Gyeonggi-do 

Business Registration Number: 314-24-80398   

Phone: 031-794-7980   Consultation Hours: Weekdays 09:00–18:00 (Closed on weekends and public holidays) 


Privacy Policy    Terms of Service    

COPYRIGHTS (C) 2026. ALL RIGHTS RESERVED.

Inverse Gas Chromatography Surface Energy Analyzer-Nova 

The iGC-SEA Nova, the latest addition to the Inverse Gas Chromatography Surface Energy Analyzer (iGC-SEA) line, retains all the unique capabilities of the original iGC-SEA instrument while offering the added ability to dry samples under high-temperature conditions. 

Applications 


Battery Materials Analysis — Measures surface energy and diffusion properties of electrode materials at high temperatures, contributing to performance enhancement Catalyst and Sorbent Research — Analyzes sorption strength and surface reactivity to enable efficient catalyst design Polymer and Composite Material Characterization — Evaluates adhesion and miscibility to understand interactions between materials Carbon-Based Materials Analysis — Precisely characterizes the surface properties of graphene, carbon nanotubes, and similar materials for advanced electronic materials development Pharmaceuticals and Active Pharmaceutical Ingredients (APIs) — Analyzes crystallinity, surface energy, and wettability to evaluate formulation stability and blending compatibility Fibers and Textiles — Analyzes surface modification status and energy changes before and after treatment, supporting evaluation of dyeability and functional treatment efficiency 

Key Features 




  • High-Temperature Analysis Capability — Analyzes sample surface properties and diffusion coefficients across a temperature range of 30 °C to 500 °C, providing an advantage for material characterization under high-temperature environments
  • In-Situ Sample Pre-Treatment — Modular accessories enable direct sample pre-treatment within the instrument, allowing analysis under various conditions while maintaining sample integrity
  • Versatile Probe Gas Selection — Precisely measures diverse material properties — including surface energy, acid-base interactions, and sorption isotherms — using up to 12 different probe gases
  • Fully Automated Operation — Dedicated software enables experimental automation, with a user-friendly interface that simplifies experimental setup and data analysis
  • Optional Humidity Control — An optional humidity control feature can be added, enabling analysis of sample property changes under diverse humidity conditions

What Are the Advantages of iGC-SEA Nova? 

01

High-Temperature Capability 


With a temperature range of 30 °C to 500 °C, the iGC-SEA Nova's high-temperature column oven enables laboratories to perform sample preparation, surface energy analysis, and determination of diffusion coefficients — such as for carbon materials — at application-relevant temperatures. 

02

Rapid Surface Characterization of Highly Active Substrates 


The iGC-SEA Nova efficiently characterizes highly active substrates through its rapid surface analysis capabilities.  

03

Unmatched Accuracy and Reliability 


The iGC-SEA Nova from Surface Measurement Systems combines Inverse Gas Chromatography principles with innovative instrument features to deliver outstanding accuracy and exceptional reproducibility. 

04

Fully Automated Operation 


Through the innovative design of the Inverse Gas Chromatography Surface Energy Analyzer Nova and its dedicated control software, experiments can be performed with complete automation — dramatically reducing user hands-on time. 

05

Experimental Flexibility with Up to 12 Probe Gases 


Using up to 12 different probe gases, researchers can conduct diverse experiments and obtain a broad range of Inverse Gas Chromatography data. 

06

In-Situ Sample Pre-Treatment 


Modular accessories enable direct sample pre-treatment within the instrument, allowing researchers to precisely track how solid surface properties change under various temperatures and conditions. 


Inverse Gas Chromatography Surface Energy Analyzer — iGC-SEA Nova 

The iGC-SEA Nova delivers a diverse range of innovative material characterization capabilities. 

iGC-SEA Nova Specifications 


Specifications 


Temperature Range
30°C ~ 500°C (high-temperature column oven installed)
Number of Probe Gases
Up to 12 different probe gases available
Sample Pre-Treatment
In-situ pre-treatment supported (via modular accessories)
Operation Mode
Fully automated experiment execution (dedicated control software included)
Accuracy & Reproducibility
High accuracy and reproducibility achieved through iGC principles and innovative instrument capabilities
Humidity Control Option
Relative humidity control 0% ~ 90% (when optional humidity module is used)
Data Analysis Software
User-friendly iGC wizard-based software provided
Application Areas
Battery materials, catalysts, polymers, carbon materials, and various other high-temperature applications

Inverse Gas Chromatography Technique 

Surface Characterization of Carbon Black for Energy Storage 

Vulcan XC 72 is a highly electrically conductive carbon black used in a wide range of applications, including batteries, fuel cells, conductive papers, and catalyst supports. This material offers exceptional conductivity and plays a critical role as a support material in both anode and cathode electrodes at low loading levels — particularly in Polymer Electrolyte Membrane Fuel Cells (PEMFCs). BET SSA: 128.8 m²/g. 

100+ Clients Trust Our Analytical Technology  

Start working with SNT Korea today.

Contact us for detailed technical consultation and measurement inquiries.  



Company Name : SNT     Address:  W 1013, The Front Misa, 11 Misagang-byeonjungang-ro, Hanam-si, Gyeonggi-do 

Business Registration Number: 314-24-80398    CEO: Lee Woo-jong    Phone: 031-794-7980    Consultation Hours: Weekdays 09:00–18:00 (Closed on weekends and public holidays) 


Privacy Policy    Terms of Service    COPYRIGHTS (C) 2026. ALL RIGHTS RESERVED.