Radiant Heat Protection Tester 

Radiant Heat Protection Tester 

Radiant Heat Protection Tester 

The ISO 6942 Radiant Heat Protection Tester is equipment that evaluates the durability of materials against radiant heat. 


This test is an important evaluation of how well clothing, protective equipment, and materials can withstand heat-induced damage in high-temperature environments. 


The ISO 6942 standard specifies testing methods for measuring the effects of radiant heat on the human body or objects.


The Radiant Heat Protection Tester based on the ISO 6942 standard is testing equipment used to evaluate protective performance against radiant heat, and is primarily used to assess the heat resistance of protective clothing, protective equipment, clothing, and materials. 


This equipment directly applies radiant heat at a constant intensity to measure how well the test object can withstand it. 


Since radiant heat propagates in the form of thermal radiation, this test is essential for demonstrating the effective thermal defense performance of protective equipment used in various industries.

Key Features  



Radiant Heat Control Function Precisely controls the heat generated from the radiant heat source, enabling testing under various environments.


Automated Testing Process Applies radiant heat uniformly to the test object and automatically handles test progression and result analysis through an automated system.


Time and Temperature Control Temperature and heat exposure time can be finely adjusted during testing, allowing experimentation under various test conditions.


Material Damage Analysis Measures damage or deformation that occurs after the material is exposed to radiant heat, evaluating heat resistance.


Safety Features Equipped with overheat protection devices and emergency stop functions designed with safety in mind during radiant heat emission, allowing tests to be conducted safely.

Key Analysis Results 


  • Breakthrough Time: The time at which a specific gas first begins to be detected after passing through the column
  • Saturation Time: The point at which the column becomes fully saturated and adsorption no longer occurs
  • Dynamic Adsorption Capacity: The actual adsorption amount calculated using the breakthrough curve
  • Selectivity: Measures how selectively the material adsorbs specific components in a multi-component mixture

Equipment Specifications  


Specifications 


Test TypeRadiant Heat Resistance Test
Test SpecimenClothing, protective equipment, various materials
Radiant Heat SourceHigh-temperature radiant heat emitter (temperature-controllable)
Temperature Range100°C ~ 1100°C or above (may vary depending on test conditions)
Radiant Heat Intensity20 kW/m² ~ 150 kW/m² (user-adjustable; varies with radiant heat intensity)
Test Duration10 sec ~ 300 sec (user-adjustable; supports various environmental test scenarios)
Test StandardISO 6942
Temperature Control Accuracy±1°C
Test SystemAutomated temperature and time control system
Heat Source AdjustmentPrecise adjustment of radiant heat intensity and temperature
Result RecordingAutomated post-test result logging and analysis
Specimen SizeVarious sizes of protective clothing, garments, and materials
Material Damage AnalysisAssessment of thermal damage and heat resistance of materials exposed to radiant heat
Temperature Measurement Range-50°C ~ 1100°C (measured across specimen and surrounding environment)
Safety FeaturesOverheat protection, automatic test termination, emergency stop function
Power Requirements220V / 380V, 50-60Hz (may vary depending on model)
DimensionsApprox. 1.5m × 1.5m × 2m (may vary depending on model)
WeightApprox. 300kg ~ 500kg (may vary depending on model)
User InterfaceDigital display with touchscreen for intuitive operation and configuration
Test Environment RequirementsIndoor environment; temperature and time control required during radiant heat exposure

Software Support Specifications 



Test Setup Customizable user settings for temperature, radiant heat intensity, time, and more.


Data Recording and Analysis Real-time data recording, automatic analysis, and result visualization (graphs and charts).


Report Generation Automatically generates reports after testing and saves them in PDF or Excel format.


Automation Automated test progression, temperature and time control, with warning and notification functions.


Compatibility Supports integration with various equipment; remote updates available.


Security User login and role-based access management.

The Analytical Technology Trusted by 100+ Clients.  
Partner with S&T Today. 

Elevate your analytical environment with our precision technology and accumulated expertise. 


Company Name : SNT    CEO: Lee Woo-jong

Address:  W 1013, The Front Misa, 11 Misagang-byeonjungang-ro, Hanam-si, Gyeonggi-do 

Business Registration Number: 314-24-80398   

Phone: 031-794-7980   Consultation Hours: Weekdays 09:00–18:00 (Closed on weekends and public holidays) 


Privacy Policy    Terms of Service    

COPYRIGHTS (C) 2026. ALL RIGHTS RESERVED.

Radiant Heat Protection Tester 

The ISO 6942 Radiant Heat Protection Tester is equipment that evaluates the durability of materials against radiant heat. This test is an important evaluation of how well clothing, protective equipment, and materials can withstand heat-induced damage in high-temperature environments. The ISO 6942 standard specifies testing methods for measuring the effects of radiant heat on the human body or objects.


The Radiant Heat Protection Tester based on the ISO 6942 standard is testing equipment used to evaluate protective performance against radiant heat, and is primarily used to assess the heat resistance of protective clothing, protective equipment, clothing, and materials. This equipment directly applies radiant heat at a constant intensity to measure how well the test object can withstand it. Since radiant heat propagates in the form of thermal radiation, this test is essential for demonstrating the effective thermal defense performance of protective equipment used in various industries.

Key Features  




Radiant Heat Control Function Precisely controls the heat generated from the radiant heat source, enabling testing under various environments.


Automated Testing Process Applies radiant heat uniformly to the test object and automatically handles test progression and result analysis through an automated system.


Time and Temperature Control Temperature and heat exposure time can be finely adjusted during testing, allowing experimentation under various test conditions.


Material Damage Analysis Measures damage or deformation that occurs after the material is exposed to radiant heat, evaluating heat resistance.


Safety Features Equipped with overheat protection devices and emergency stop functions designed with safety in mind during radiant heat emission, allowing tests to be conducted safely.

Key Analysis Results  


  • Breakthrough Time: The time at which a specific gas first begins to be detected after passing through the column
  • Saturation Time: The point at which the column becomes fully saturated and adsorption no longer occurs
  • Dynamic Adsorption Capacity: The actual adsorption amount calculated using the breakthrough curve
  • Selectivity: Measures how selectively the material adsorbs specific components in a multi-component mixture

Equipment Specifications  


Specifications 


Test Type
Radiant Heat Resistance Test
Test Specimen
Clothing, protective equipment, various materials
Radiant Heat Source
High-temperature radiant heat emitter (temperature-controllable)
Temperature Range
100°C ~ 1100°C or above (may vary depending on test conditions)
Radiant Heat Intensity
20 kW/m² ~ 150 kW/m² (user-adjustable; varies with radiant heat intensity)
Test Duration
10 sec ~ 300 sec (user-adjustable; supports various environmental test scenarios)
Test Standard
ISO 6942
Temperature Control Accuracy
±1°C
Test System
Automated temperature and time control system
Heat Source Adjustment
Precise adjustment of radiant heat intensity and temperature
Result Recording
Automated post-test result logging and analysis
Specimen Size
Various sizes of protective clothing, garments, and materials
Material Damage Analysis
Assessment of thermal damage and heat resistance of materials exposed to radiant heat
Temperature Measurement Range
-50°C ~ 1100°C (measured across specimen and surrounding environment)
Safety Features
Overheat protection, automatic test termination, emergency stop function
Power Requirements
220V / 380V, 50-60Hz (may vary depending on model)
Dimensions
Approx. 1.5m × 1.5m × 2m (may vary depending on model)
Weight
Approx. 300kg ~ 500kg (may vary depending on model)
User Interface
Digital display with touchscreen for intuitive operation and configuration
Test Environment Requirements
Indoor environment; temperature and time control required during radiant heat exposure

Software Support Specifications  



 

- Test Setup Customizable user settings for temperature, radiant heat intensity, time, and more.


- Data Recording and Analysis Real-time data recording, automatic analysis, and result visualization (graphs and charts).


- Report Generation Automatically generates reports after testing and saves them in PDF or Excel format.


- Automation Automated test progression, temperature and time control, with warning and notification functions.


- Compatibility Supports integration with various equipment; remote updates available.


- Security User login and role-based access management.

100+ Clients Trust Our Analytical Technology  

Start working with SNT Korea today.

Contact us for detailed technical consultation and measurement inquiries.  



Company Name : SNT     Address:  W 1013, The Front Misa, 11 Misagang-byeonjungang-ro, Hanam-si, Gyeonggi-do 

Business Registration Number: 314-24-80398    CEO: Lee Woo-jong    Phone: 031-794-7980    Consultation Hours: Weekdays 09:00–18:00 (Closed on weekends and public holidays) 


Privacy Policy    Terms of Service    COPYRIGHTS (C) 2026. ALL RIGHTS RESERVED.