Flame Spread Tester
Flame Spread Tester
Flame Spread Tester
EN 13274-4 is one of the standards for testing the flame resistance of Respiratory Protective Devices (RPD).
This standard presents testing methods for evaluating the safety and fire resistance of respiratory protective devices when exposed to flames. The EN 13274-4 Flame Resistance Tester is equipment that evaluates how much fire resistance respiratory protective devices have when exposed to flames.
This test focuses on verifying whether the materials and structure of respiratory protective devices remain undamaged by flames and can maintain their user protection function.
Key Features

Flame Resistance Measurement Respiratory protective devices are exposed to flames to test their fire resistance.
Tests are generally conducted by setting precise flame temperatures and exposure times.
Material Heat Resistance Evaluation After testing, the deformation, non-combustion, or damage of the respiratory protective device is evaluated.
Automated Test Progression Evaluates how well the material resists flames and measures the degree of burning or melting.
Result Analysis Analyzes the results after testing to determine the flame resistance of the respiratory protective device.
Equipment Specifications
Specifications
| Test Specimen | Respiratory Protective Device (RPD) |
| Test Method | Evaluation of flame resistance and fire protection performance through flame exposure |
| Flame Generation Device | Gas flame generator (propane gas) |
| Test Temperature | Flame temperature settable up to 1,000°C or above |
| Exposure Duration | Typically 10 sec ~ 30 sec (adjustable according to test standard) |
| Flame Stand-off Distance | 60 cm or less (distance from specimen to flame) |
| Test Procedure | Automated test execution; post-test evaluation of deformation and damage to the RPD |
| Additional Features | Flame resistance assessment, non-combustion evaluation, material deformation measurement |
| Temperature Control | Precision temperature control unit maintains consistent flame temperature |
| Result Recording | Automatic result logging with export to PDF and Excel formats |
| Safety Devices | Emergency stop system, overheat protection device |
| End-of-Test Notification | Automatic alert upon test completion |
| Power Supply | 220V / 50Hz or 110V / 60Hz (configurable to local voltage standards) |
| User Interface | Touchscreen and digital display for intuitive operation and control |
Software Support Specifications

Test Setup Users can configure flame temperature, exposure time, flame distance, and more.
Data Recording and Analysis Automatically records temperature, time, material reactions, and other data generated during testing.
Report Generation Automatically generates reports after testing and saves them in PDF or Excel format.
Automation Automatically controls test progression, flame exposure time, and flame temperature.
Compatibility Supports integration with various equipment; remote updates available.
Security Maintains security through user authentication and role-based access control.
The Analytical Technology Trusted by 100+ Clients.
Partner with S&T Today.
Elevate your analytical environment with our precision technology and accumulated expertise.

Company Name : SNT CEO: Lee Woo-jong
Address: W 1013, The Front Misa, 11 Misagang-byeonjungang-ro, Hanam-si, Gyeonggi-do
Business Registration Number: 314-24-80398
Phone: 031-794-7980 Consultation Hours: Weekdays 09:00–18:00 (Closed on weekends and public holidays)
Flame Spread Tester
EN 13274-4 is one of the standards for testing the flame resistance of Respiratory Protective Devices (RPD). This standard presents testing methods for evaluating the safety and fire resistance of respiratory protective devices when exposed to flames. The EN 13274-4 Flame Resistance Tester is equipment that evaluates how much fire resistance respiratory protective devices have when exposed to flames. This test focuses on verifying whether the materials and structure of respiratory protective devices remain undamaged by flames and can maintain their user protection function.
Key Features

Flame Resistance Measurement Respiratory protective devices are exposed to flames to test their fire resistance. Tests are generally conducted by setting precise flame temperatures and exposure times.
Material Heat Resistance Evaluation After testing, the deformation, non-combustion, or damage of the respiratory protective device is evaluated.
Automated Test Progression Evaluates how well the material resists flames and measures the degree of burning or melting.
Result Analysis Analyzes the results after testing to determine the flame resistance of the respiratory protective device.
Specifications
Test Specimen | Respiratory Protective Device (RPD) |
Test Method | Evaluation of flame resistance and fire protection performance through flame exposure |
Flame Generation Device | Gas flame generator (propane gas) |
Test Temperature | Flame temperature settable up to 1,000°C or above |
Exposure Duration | Typically 10 sec ~ 30 sec (adjustable according to test standard) |
Flame Stand-off Distance | 60 cm or less (distance from specimen to flame) |
Test Procedure | Automated test execution; post-test evaluation of deformation and damage to the RPD |
Additional Features | Flame resistance assessment, non-combustion evaluation, material deformation measurement |
Temperature Control | Precision temperature control unit maintains consistent flame temperature |
Result Recording | Automatic result logging with export to PDF and Excel formats |
Safety Devices | Emergency stop system, overheat protection device |
End-of-Test Notification | Automatic alert upon test completion |
Power Supply | 220V / 50Hz or 110V / 60Hz (configurable to local voltage standards) |
User Interface | Touchscreen and digital display for intuitive operation and control |
Software Support Specifications

- Test Setup Users can configure flame temperature, exposure time, flame distance, and more.
- Data Recording and Analysis Automatically records temperature, time, material reactions, and other data generated during testing.
- Report Generation Automatically generates reports after testing and saves them in PDF or Excel format.
- Automation Automatically controls test progression, flame exposure time, and flame temperature.
- Compatibility Supports integration with various equipment; remote updates available.
- Security Maintains security through user authentication and role-based access control.
100+ Clients Trust Our Analytical Technology
Start working with SNT Korea today.
Contact us for detailed technical consultation and measurement inquiries.

Company Name : SNT Address: W 1013, The Front Misa, 11 Misagang-byeonjungang-ro, Hanam-si, Gyeonggi-do
Business Registration Number: 314-24-80398 CEO: Lee Woo-jong Phone: 031-794-7980 Consultation Hours: Weekdays 09:00–18:00 (Closed on weekends and public holidays)